boiler, steam boiler, thermic fluid heater, hot air generator, hot water gnerator, heat exchanger, thermic fluid heater
Other Product
:: Ambica Boiler is mainly concerned in manufacturing Steam Boilers, Heat Exchangers , Incinerators and Unfired Pressure Vessels ( Gas Storage and Mobile tanks) according to Indian Boiler Regulation 
CLICK ON IMAGE FOR ENLARGE VIEW
ISO 9001 : 2000

cert: QI7630/08

 
 

 Solid Fuel Fired - Thermic Fluid Heater

  
Parameter Unit

Model

ABTH-400 ABTH-600 ABTH-1000 ABTH-1500

ABTH-2000

Heat Output

Kcal/Hr

4,00,000

6,00,000

10,00,000

15,00,000

20,00,000

Max.Fluid Outlet Temperature

oC

300

Max. Head at heater Outlet

M/c

27

Efficiency on GCV With APH+

%

75

Without APH+

%

70

Rated fuel consumption Steam Coal

Kg/hr

118

177

296

444

592

Lignite

Kg/hr

152

228

381

571

762

Agro-waste

Kg/hr

162

242

404

606

808

Thermic Fluid Pump Motor

Kw

9.30

11.00

15.00

22.00

30.00

I.D.Fan Motor

Kw

3.70

5.62

11.25

11.25

15.00

Over fire fan motor

Kw

-

1.50

2.25

3.70

3.70

Total Load

Kw

13.00

18.12

28.50

36.95

48.70

Expansion Tank Capacity

Liters

800

800

1000

1000

1250

Overall Dimensions

Length

mm

4600

6000

7500

7800

10000

With

mm

3800

4000

4500

5400

6200

 

Home  |  Product  |  Profile  |  Contact | Sitemap | Resource

 